BP-600 series NIBP/SpO2 PATIENT MONITOR

Features:

- Compact and portable, allowing for uninterrupted monitoring with built-in battery
- Display of NIBP, SpO2 and Pulse Rate via LED with high brightness
- 3 configurations selectable
- Manual/auto/continuous measurement of NIBP
- Auto audible and visual alarms
- Storage of NIBP data up to 900 groups or SpO2 data up to 22 hours
- External printer available
- Suitable for adult, pediatric and neonatal patient

Safety

IEC6060-1 approved, CE marking according to MDD93/42/EEC

Dimension and Weight

Dimension: 6cm (H) x 18cm (W) x 22cm (D)   Weight: 1.8 kg

 

NIBP

Method: Oscillometric

Mode: Manual/Automatic/Continuous

Measurement unit: mmHg/Kpa selectable

Automatic measurement interval: 1, 2, 3, 5, 10, 30, 45,60,90,120, 180,240,480 minutes

Measurement range: Adult/Pediatric: 15-255mmHg

Neonate: 10-135mmHg

Alarm: Systolic, Diastolic, Mean

Alarm Range: 15~255mmHg

Resolution: 1mmHg

Overpressure Protection:

Adult/Pediatric Mode 290mmHg

Neonatal Mode 145mmHg

 

SpO2

Measurement range: 0~100%

Resolution: ‘ΐ1 %

Accuracy: 2 % (70% ~ 100%), 0~69% unspecified

Alarm range: 0~100%

Pulse Rate

Range: 0~254bpm

Resolution: 1bpm

Accuracy: ‘ΐ1bpm

Alarm range: 0~254bpm 

Review

Trend review: Storage and review of NIBP data up to 900 groups

or SpO2 data up to 22 hours

‘‘

BP-600 I NIBP/PR

BP-600 II NIBP/SpO2/PR

BP-600 III SpO2/PR  

‘‘

 

SB-9101 NON-INVASIVE BP MONITOR

9101.jpg (12529 bytes)‘ρ Operational principle£Ίoscillometric method  
‘ρ High capability of data storage  
‘ρ Double protection  
‘ρ Anti high frequency interference design  
‘ρ Exact and stable result
 

‘‘

‘‘

9102.jpg (12677 bytes)SB-9102 BP/ SpO2 MONITOR

‘ρ Original BCI

‘ρ Import pump

‘ρ High capability of storage

Feature: 

1.Auto Measure Manual/auto measurement of NIBP  

2.Protection Three protections for operation safety 

3.Memory Storage of NIBP data up to 2500 groups 

4.Contiunous Measure Three minutes uninterrupted monitoring for measurement 

5.Alarm Auto audible alarm according to different conditions

1.Measure Range:

Systolic Pressure:              5.3-34.7kpa (40-260mmHg)

Diastolic Pressure:             2.7-29.3kpa (20-220mmHg)

Average Artery Pressure:  4.0-32.0kPa (30-240mmHg)

SpO2:                                0-99%

Pulse Rate:                        30-250bPm 

2.Measure Accuracy:

Pressure:                           3mmHg

SpO2:                                ‘ΐ1% (at 70-100%)

                                          ‘ΐ2% (at 50-69%)

Pulse Rate:                        ‘ΐ2%

Measure Interval:               0-90 minutes 

3.Electric Parameter:

Power Supply:                    AC 220V‘ΐ10%  50Hz‘ΐ2%  Power consumption: 20W

4.Dimension:   260‘Α240‘Α115(mm)  
5.Weight:   
5Kg

‘‘

‘‘

‘‘